Solar VFD DC250-880V to 3PH 380V 15/18.5/22KW Variable Frequency Drive Converter for Motor Speed Control Inverter

ر.ع.168.87ر.ع.201.48

Hign-concerned Chemical: None is_customized: Yes Output Frequency: 0-300HZ Model Number: ZA-D11T3 Type: DC/AC Inverters Weight: 6.7kgs Size: 173*65*151MM Output Type: triple Brand Name: ZESTABLE Origin: Mainland China Certification: CE Input Voltage: DC 250-880V Output Voltage: 3PH 0-460VAC Power: 0.4~500KW Low Output Frequency: 0-300Hz High Output Frequency: 0-3000Hz Input Frequency: 47~63Hz Technical Index and Specification ZA-D11S2 VFD Input : 1> : 1-phase 160-260VAC;47-63HZ 2> : DC150-400V solar vfd Output: Voltage : 3 – phase […]

SKU: 1005007313054487
Category: ,

Description

  • Hign-concerned Chemical: None
  • is_customized: Yes
  • Output Frequency: 0-300HZ
  • Model Number: ZA-D11T3
  • Type: DC/AC Inverters
  • Weight: 6.7kgs
  • Size: 173*65*151MM
  • Output Type: triple
  • Brand Name: ZESTABLE
  • Origin: Mainland China
  • Certification: CE
  • Input Voltage: DC 250-880V
  • Output Voltage: 3PH 0-460VAC
  • Power: 0.4~500KW
  • Low Output Frequency: 0-300Hz
  • High Output Frequency: 0-3000Hz
  • Input Frequency: 47~63Hz

Technical Index and Specification

ZA-D11S2 VFD

Input :

1> : 1-phase 160-260VAC;47-63HZ

2> : DC150-400V solar vfd

Output: Voltage : 3 – phase ; 0~260V;0-300Hz

ZA-D11T3 VFD

Input :

1> : 3-phase 320-460V;47-63HZ

2> : DC300-700V solar vfd

Output: Voltage : 3 – phase ; 0~460V;0-300Hz

Control Mode :Vector control
Protective Function :Overcurrent, overvoltage, undervoltage, module fault, electric thermal relay, overheat, short circuit,
default phase of input and output, motor parameter adjustment abnormality, internal memory fault, etc.

For more function pls ask me for user’s manual >>>>>>>>>>>>>>>>>>>>>>>>>>>>

Safety Precaution:
1. Before wring, please make sure that the input power is off.
2. The wring work should be operated by the professional electrical engineer.
3. The grounding terminals must be connected with the ground.
4. Having paused circuit wiring emergently, please make sure that the check is effective.
5. Do not connect the output wire of the inverter with the shell, and pay attention that the
output wire should not be short-circuited.
6. Please check whether the voltage of the AC main circuit power is consistent with the rated voltage of the inverter.
7. Do not do the voltage withstand test on the inverter.
8. Please connect the brake resistor according to the wiring diagram.
9. Do not connect the power to the U, V, W output terminals.
10. Do not connect the contactor with the output circuit.

Additional information

Color

15KW, 18.5KW, 22KW

Input Voltage

DC 250-880V

Output Voltage

3PH 0-460VAC

Reviews

There are no reviews yet.

Be the first to review “Solar VFD DC250-880V to 3PH 380V 15/18.5/22KW Variable Frequency Drive Converter for Motor Speed Control Inverter”

Your email address will not be published. Required fields are marked *